description1
Zipper closure 1/4 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
AODE Reaction Kettle AOS-20 Oil Temperature Control Unit

At the initial stage of use of the oil temperature machine, the heat transfer oil is replenished into the pipeline system through the expansion oil tank, forced to circulate the liquid phase through the high temperature pump, and circulated between the equipment to be controlled and the unit system. After the heat transfer oil comes out of the heating device of the unit, the temperature rises. After entering the temperature control equipment, the heat is absorbed, returned to the heating pipe of the system to continue heating, and injected into the equipment to be used again, Until the heating equipment reaches the set temperature.

What should be paid attention to in the purchase and use of the oil temperature machine?
1. The large oil temperature machine cannot be used to adjust the temperature of several pairs of models, because the large cannot give consideration to the small.
2. One molding machine uses one or several oil temperature machines, and the temperature difference of each oil temperature machine cannot be large.
3. The pipe shall not be used for divergence, and the opening size of the valve shall not be adjusted at will. It shall be fully opened for use.
4. The temperature sensor of the same model feeds back to the thermostat for control.
5. Check the flow and calibrate the thermometer.
6. The circulating water with good quality shall be used, and the cooling water or water overflow shall not be directly injected.

 

Item Unit Model AOS-20
Temp control range ° Inlet water temperature +45°-180°
Temp control accuracy ° PID+-1°
Motor supply   AC3P 380/400V50Hz(3phase+Earth)
Heat transfer medium   Thermal conductive oil
Cooling method   Indirect cooling
Heating capacity Kw 9
Motor power Kw 1.5
Pump flow Lpm 120
Pump head m 17
Max.power consumption Kw 10.5
Alarm function   Pump reversal/Oil shortage/Overload/Abnormal heating
Cooling water pipe Inch 1/2
Circulating oil pipe Inch 3/8*4
Size(L x W x H) mm 630*325*745

 